Impact Testing Machine رایمند سیستم آزما <



ZBC1000 Series Pipe Pendulum Impact Testing Machine

Features: This instrument is special for dynamic impact resistance test of plastic pipe(PPR,PVC-C). Easy-to-operate and high efficiency. Real-time data acquisition has an advantage in continuous impact tests in lab. Major Technical Parameters
    • Max impact energy: 15J,50J
    • Raising angle: 150°
    • Impact speed: 3.8m/s
    • Length of pendulum : 395mm
    • Striking edge included angle: 30°
    • Striking edge radius: 2mm
    • Standard specimen anvil radius: 1mm
    • Standard specimen anvil front bevel: 5°
    • Standard specimen anvil inner side bevel: 10°
    • Arc specimen anvil front bevel: 60°
    • Arc specimen anvil inner side bevel: 0°
    • Arc specimen anvil radius: 2mm
    • Specimen
    • Overall dimension:480Χ340Χ805mm
    • Overall weight:about 100kg


ZBC1000 Series Plastic Pendulum Impact Testing Machine

Features: This model is for impact resistance test of non-metal materials under dynamic load. It’s the necessary testing instrument for non-metal material factories, as well as for new material development in scientific research institutes. Its advantages are more outstanding in continuous impact test and large quantities impact test. Special control panel and display can real-time display impact energy, impact ductility, pendulum raising angles. Able to print test data and each test average data as connecting to dot printer. Conform to GB/T1043 , GB/T1843 , ISO 179 , ISO 180, and other standards. Specifications:
    • Impact energy:
    Charpy: 1J,2J,4J,7.5J ,15J,25J, 50J
    Izod: 2.75J,5.5J,11J,22J
    • Impact Speed:
    Charpy: 2.9m/s(less than/equal 5J), 3.8m/s(more than 5J)
    Izod: 3.5m/s
    • Striker Raising angle: 150°
    • Main models:
    ZBC1100-1/2,ZBC1200-1/2,ZBC1400-1/2,ZBC1750-1/2
    ZBC1151-1/2,ZBC1251-1/2,ZBC1501-1/2
    Note: -1 is point and dial display, -2 is digital display


ZBC2000 Series automatic pendulum impact testing machine

Main frame Specifications:
    • Model: ZBC2152 ZBC2302 ZBC2452 ZBC2602 ZBC2752
    • Max impact energy(J): 150 300 450 600 750
    • Pendulum moment of force(Nm) 80.3848 160.7695 241.1543 321.5390 401.9238
    • Distance from the axis of support to the center of percussion: 750mm
    • Angle of fall: 150°
    • Angle resolution: 0.1°
    • Impact speed: 5.24m/s
    • Charpy span: 40mm
    • Anvil edge radius: 1~1.5mm
    • Anvil bevel: 11±1°
    • Striking edge radius: 2~2.5mm
    • Striking edge included angle: 30±1°
    • Striking edge thickness: 16mm
    • Specimen size: 10mm(7.5mm/5mm)Χ10mmΧ55mm
    • Overall dimension: 960mmΧ 735mmΧ 1500mm
    • Overall weight: 900Kg
    • Power supply: Three phases, 380V±10%,2A
Main Frame technical features:
    • Apply industrial PLC control system to control pendulum performance, high accuracy rotating encoder to detect pendulum real-time position. The system is stable, reliable and accurate.
    • Monitor real-time displays pendulum angle and test data and easy to input parameters and operate.
    • Integrity design and foundry processing of main frame seat and columns provide high stability and high rigidity.
    • Columns are symmetry and pendulum is bearing on a single beam. Simple structure and high machined accuracy.
    • High accuracy bearing shaft with low friction, energy absorption is less than 0.3%,
    • Standard double stage reduction gear replaces of old transmission system, with high efficiency, which eliminates transmission problems.
    • Pendulum holding is using buffer design preventing holding shocking and possible damage and keeping angle of fall constantly unchanged.
    • Round pendulum design effectively reduces wind resistance. Striking edge is assembled by bolted fixing wedge pressing block and easy to change. Rigid beam and pendulum prevent axial and lognitudinal vibration after impact.
    • Complete closing protective shield is made of tempered glass, which fully secures operator safety.
Accessories:
    • Low temperature Chamber
    • Model: ZDW1102 ZDW2601
    • Cooling: liquid nitrogen, compressor
    • Temperature range:
    ambient temperature to -100?, ambient temperature to -60
    • Cooling spped:
    ambient temperature to -100?, about 20 minutes
    ambient temperature to -60?, about 80 minutes
    • Liquid nitrogen tank capacity: 15L/160L (customized), weight:80Kg/200Kg
    • Power supply: Single-phase AC 220V/2A, 50Hz
    Single-phase AC 220V/8A, 50Hz
    • Effective space for specimen: 120Χ120Χ80mm (LXWXH)
    • Charpy specimen placing quantity at one time : 120 pieces
    • Temperature gradient: ?0.5
    • Temperature vibration: ?±1
    • Temperature accuracy: 0.3
    • Temperature resolution: 0.1
    • Cooling media: absolute ethyl alcohol (99.7%)
    • Note: ZDW1102 effective space can be customized to satisfy impact test requirements of DT, NDT or DWTT
Automatic specimen feeding device Features:
    • 40 pieces specimens can be fitted at one time
    • Chamber cools down specimens by circulation, cooling media doesn’t contact specimens directly.
    • Joint with main frame smoothly, automatic running, time and labor saving, and more safety.
    • All actions are pneumatic, with high accuracy and low failure rate.
Specimen reclaiming device Features:
    • Micro motor drive, automatically reclaim specimens after impact. Equipped with full closing protective shield . Able to collect all specimen fragment automatically and prevent hammer blocked.
    • Unique specimen sorting function, able to separate qualified and unqualified specimens and collect to different boxes.
Computer and software:
    • Micro computer control metal impact testing machine control system is consisted of computer and PLC controller. PowertestforZBC test software is capable of saving test data in database, and export data to report template(Excel format), explore and print test report at any time.


ZBC2302 Series Automatic Pendulum Impact Testing Machine

Features: This machine is special for impact resistance test of metal under dynamic loading. It’s the necessary test instrument for metal factories, quality inspection stations, research institutes and academies. Full automatic, easy-to-operate and high efficiency. ZBC-300B(digital) is equipped with LCD display. Apply industrial use PLC controller to control pendulum raising, releasing, and impact. Able to display absorbing energy, impact ductility, pendulum raising angle, and process test data and print test report. Model: ZBC2302-1,ZBC2302-2,ZBC2302-3 -1: pointer display -2: digital display -3 :computer control Specifications :
    • Max impact energy: 150J,300J
    • Pendulum moment of force: 80.3848N.m,160.7695N.m
    • Pendulum raising angle: 150°
    • Distance from axis of support to center of percussion: 750mm
    • Impact speed: 5.2m/s
    • Charpy span: 40mm
    • Anvil support edge radius: 1-1.5mm
    • Anvil support plane bevel: 0°
    • Striking edge radius: 2-2.5mm
    • Striking edge included angle: 30°
    • Striking edge thickness: 16mm
    • Specimen size: 10 mmΧ10 mmΧ55 mm
    • Ambient temperature: 10-35?
    • Overall dimension:
    Main frame: 2140mmΧ500mmΧ1400mm
    LCD Control cabinet: 600 mmΧ400 mmΧ1000mm
    • Net weight: 450Kg
    • Power supply: Three-phases AC 380V±10% 50Hz 5A
    • Conditions: no corrosive media, no shaking, no electromagnetic interfering.


ZBC2502 Series Automatic Pendulum Impact Testing Machine

Functions and Features This machine is special for impact test of metallic materials under dynamic loading. Suitable for material analysis and inspection in Aerospace, mechanical metallurgy, academies and research institutes. ZBC-500B(digital) is equipped with LCD display. Apply industrial use PLC controller to control pendulum raising, releasing, and impact. Able to display absorbing energy, impact ductility, pendulum raising angle, and process test data and print test report. ZBC-500C (Computer control): test data is transmitted to PC through PLC controller. Software running in Windows is capable of data saving, inquiring, searching and printing. With LAN interface, data can be transmitted to LAN database if needed. Easy to operate, high reliability and strong anti-interference ability. Optional high and low temperature chamber is available to customer requirements. Models: ZBC2502-1,ZBC2502-2,ZBC2502-3 -1: pointer display -2: digital display -3: computer control

Specifications:
    • Max impact energy: 250J,500J
    • Pendulum raising angle: 150°
    • Distance from axis of support to center of percussion: 800mm
    • Impact speed: 5.4m/s
    • Charpy span: 40mm
    • Anvil support edge radius: 1-1.5mm
    • Anvil support plane bevel: 0°
    • Striking edge radius: 2-2.5mm
    • Striking edge included angle: 30°
    • Striking edge thickness: 16mm
    • Specimen size: 55 mmΧ10 mm Χ10 mm
    • Overall dimension: 2300 mmΧ640 mmΧ1500mm
    • LCD control cabinet: 600 mmΧ400 mmΧ1000mm
    • Net weight: 650Kg
    • Power supply: Three-phases AC 380V±10% 50Hz 5A
    • Conditions: no corrosive media, no shaking, no electromagnetic interference.


ZBC2503 Automatic Pendulum Impact Testing Machine

Functions: Mainly conduct dynamic tear testing of metallic thick plate materials (DT test). DT means the total absorbing energy to fracture DT specimens tested in accordance with the provisions of standard. (i.e. dynamic tear energy used to describe dynamic tear resistance of metallic materials with certain thickness, and shear fracture appearance)

Features:
    • Automatic control, press function tab to complete test process input, easy to operate, and high efficiency.
    • After impact, pendulum automatic braking, raising and latching
    • Special control panel and display can meet user requirements of operation and display. For example, display impact energy, pendulum moving angel, energy loss, no-load continuous impact times setup and so on.
    • With large impact energy, mainly used for test of ferrous metal with large impact ductility, such as steel and alloy.
    • Standard: ASTM E604-83?Standard Test Method for Dynamic Tear Testing of Metallic Materials?


Specifications:
    • Max energy: 5000J
    • Pendulum angle of fall: 135°
    • Pendulum moment of force: 2928.932N.m
    • Distance from axis of support to center of percussion: 1380mm
    • Impact Speed: 6.797m/s
    • Charpy span: 165±0.8 mm
    • Anvil edge radius: 12.7±0.8 mm
    • Anvil support plane bevel: 11°
    • Striking edge radius: 12.7±0.8 mm
    • Striking edge included angle: 30°
    • Striking edge thickness: 37mm
    • Specimen size: Length: 181±2 mm Width: 40.6±1 mm Thickness: 5,16±1 mm
    • Overall dimension: 3760mmΧ2735mmΧ3660mm
    • Overall weight: about 6500Kg

Shenzhen SANS Testing Machine Co. , LTD

Add : No.100 Chaguang Village, Shahe West Road, Nanshan, Shenzhen , China
Postcode 518055    
Tel + 86-755-26622873
          + 86-755-26700866
          + 86-013510811492
Fax + 86-755-26700052
E-mailinfo@sans.com.cn



خواهشمند است در صورت نياز به اطلاعات بيشتر در خصوص دستگاههاي معرفي شده ويا صدور پيش فاكتور ريالي و پروفرماي ارزي بااين شركت به شماره تلفن 88881191 وفكس 88664727 وياموبايل 09123600263 تماس حاصل فرمائيد.
رایمند سیستم آزما